Decibels (dB) represent three specific types of ratios: power ratios, amplitude (field quantity) ratios, and absolute level ratios (where one of the two values is a fixed reference). In every case, a decibel is not a unit of measurement itself but a logarithmic way of comparing two quantities of the same type.
Formula
The decibel formula depends on which of the three ratios you are expressing:
- Power ratio: dB = 10 × log₁₀(P₁ / P₂), where P₁ and P₂ are power values in watts (or any power unit).
- Amplitude ratio: dB = 20 × log₁₀(A₁ / A₂), where A₁ and A₂ are amplitudes such as voltage (volts), current (amperes), sound pressure (pascals), or digital signal levels.
- Absolute level: dB = 10 × log₁₀(P / P_ref) for power-based references, or 20 × log₁₀(A / A_ref) for amplitude-based references, where P_ref or A_ref is a fixed, agreed-upon value (e.g., 1 milliwatt for dBm, 20 micropascals for dB SPL).
The factor of 10 versus 20 exists because power is proportional to the square of amplitude. A 10× increase in power is 10 dB; a 10× increase in amplitude (voltage, pressure) is also 10 dB because the corresponding power increases by 100× (20 dB). The 20 multiplier is simply 10 × 2, accounting for the squaring relationship.
Worked Example
Using the default values in the calculator above, let’s compute the ratio for both quantity types.
Power case: P₁ = 100, P₂ = 10. The ratio is 100/10 = 10. In decibels: 10 × log₁₀(10) = 10 × 1 = 10.00 dB. So a 10-fold power increase is 10 dB.
Amplitude case: A₁ = 100, A₂ = 10. The ratio is 100/10 = 10. In decibels: 20 × log₁₀(10) = 20 × 1 = 20.00 dB. So a 10-fold amplitude increase is 20 dB, which corresponds to a 100-fold power increase (since power ∝ amplitude²).
The calculator’s first output shows 10.00 dB for power and 20.00 dB for amplitude, matching these results.
Why Use a Logarithmic Scale?
Human perception of sound and light is roughly logarithmic—a sound that seems twice as loud is actually about 10 times more intense. Also, real-world signals span enormous ranges: a whisper is about 10⁻¹² W/m², while a jet engine at close range is about 10² W/m², a ratio of 10¹⁴. Writing that as 140 dB is far more practical than writing out fourteen zeros. The same applies to electronics, where voltages range from microvolts to kilovolts, and to radio frequencies where powers vary by factors of billions.
Logarithms also convert multiplication into addition. If a signal passes through two amplifiers, each with a 10 dB gain, the total gain is 20 dB—you simply add the decibel values rather than multiplying the linear ratios (10 × 10 = 100, which is 20 dB). This makes system design and analysis much simpler.
The Three Ratios in Detail
1. Power ratio (dB) – This is the most basic form. It compares two power levels directly. Examples include the gain of an amplifier (output power vs. input power), the attenuation of a cable, or the difference between two transmitter outputs. The formula uses 10 × log₁₀.
2. Amplitude ratio (dB) – This compares field quantities or root-power quantities: voltage, current, sound pressure, electric field strength, or even digital sample values. Because power is proportional to the square of amplitude, the formula uses 20 × log₁₀. This is why a doubling of voltage is +6.02 dB (20 × log₁₀(2) ≈ 6.02), while a doubling of power is +3.01 dB (10 × log₁₀(2) ≈ 3.01).
3. Absolute level (dB with a suffix) – Here, the denominator is a fixed reference, so the result is an absolute quantity, not a relative comparison. Common examples:
- dBm – reference is 1 milliwatt (0.001 W). 0 dBm = 1 mW; 30 dBm = 1 W; 40 dBm = 10 W.
- dBW – reference is 1 watt. 0 dBW = 1 W; 30 dBW = 1 kW.
- dBµV – reference is 1 microvolt (amplitude ratio). Used in radio receiver measurements.
- dB SPL – reference is 20 micropascals (the nominal threshold of human hearing). 0 dB SPL is near silence; 120 dB SPL is painful.
- dBi – reference is an isotropic (perfectly spherical) antenna; used for antenna gain.
Common Mistakes and Misconceptions
The most frequent error is using the 20× formula for power values or the 10× formula for amplitudes. If you mistakenly use 20 × log₁₀ for a power ratio, you will double the decibel value. Always ask: are the two numbers watts (or milliwatts), or are they volts, pascals, or similar? If they are watts, use 10; otherwise, use 20.
Another common mistake is treating dB as an absolute unit. “50 dB” without a reference is meaningless unless you are comparing two unnamed quantities. When someone says “the amplifier has 50 dB gain,” they mean the output power is 10^(50/10) = 100,000 times the input power. But “the sound is 50 dB” is incomplete—it should be “50 dB SPL” (relative to 20 µPa).
A third misconception is that +3 dB means “twice as loud.” In reality, +3 dB represents exactly twice the power, but perceived loudness roughly doubles with about +10 dB. A 3 dB increase is barely noticeable to most listeners. Similarly, a 10 dB increase sounds about twice as loud but is ten times the power.
Finally, remember that decibels are always ratios of the same unit type. You cannot compare volts to watts directly in dB. If you have a voltage and a power, you must first compute the power from the voltage (using the impedance) before taking the ratio.
How to Read Decibel Values in Practice
Here are useful reference points to build intuition:
- 0 dB – the ratio is 1:1 (equal values).
- 3 dB – power is doubled (amplitude is multiplied by √2 ≈ 1.414).
- 6 dB – amplitude is doubled (power is quadrupled).
- 10 dB – power is ×10 (amplitude is ×√10 ≈ 3.162).
- 20 dB – amplitude is ×10 (power is ×100).
- −3 dB – power is halved (amplitude is ×0.707). This is the standard “half-power” or “cutoff” point in filter and speaker specifications.
When you see a spec like “frequency response ±3 dB from 20 Hz to 20 kHz,” it means that within that range, the output power never deviates by more than a factor of two from the nominal level. A “6 dB/octave” filter slope means that for every doubling of frequency (an octave), the output drops by 6 dB (amplitude halves).
Limits and Caveats
The decibel scale breaks down when one of the two quantities is zero. You cannot take the logarithm of zero, so a ratio of a value to zero is undefined. In practice, this rarely matters because you are comparing non-zero signals. Also, the decibel is a dimensionless unit—it has no physical dimension, only a mathematical one. This is why you can say “10 dB” without specifying whether you mean watts or volts, as long as the context is clear.
For absolute levels, the reference matters enormously. A 0 dBm signal is 1 mW, but 0 dBW is 1 W—a 30 dB difference. Always check the suffix. In audio, dB SPL uses a pressure reference, while dBu and dBV use voltage references (0.775 V and 1 V respectively). Mixing these up is a classic source of error in audio engineering.
Finally, decibels are not additive across different references. You cannot add 20 dB SPL to 30 dBm and get a meaningful result. You can only add decibel values when they share the same reference or when you are computing a chain gain (e.g., amplifier gain + cable loss).
Frequently Asked Questions
Why is 3 dB half power but 6 dB half amplitude? Because power is proportional to amplitude squared. If amplitude is reduced by a factor of 0.707 (which is −3 dB in amplitude), then power is reduced by 0.707² = 0.5, which is −3 dB in power. So −3 dB always means half power, and −6 dB always means half amplitude.
What is the difference between dB and dBA? dB is a plain ratio. dBA (or dB(A)) is a decibel reading that has been frequency-weighted to approximate human hearing sensitivity. Human ears are less sensitive to low and very high frequencies, so dBA filters out those extremes. A sound measured as 80 dB SPL might be 75 dBA depending on its frequency content.
Can decibels be negative? Yes. A negative decibel value simply means the first quantity is smaller than the reference. For example, −10 dB means the power is one-tenth of the reference. −20 dB means the amplitude is one-tenth of the reference. Negative values are common in attenuation, noise floors, and signal loss.
How do I convert dB back to a linear ratio? For power, use ratio = 10^(dB/10). For amplitude, use ratio = 10^(dB/20). For example, 30 dB power gain means 10³ = 1000×. 40 dB voltage gain means 10² = 100×.
Is 0 dB absolute silence? No. 0 dB SPL is the nominal threshold of human hearing for a young, healthy ear at 1 kHz, but it is not absolute silence. Many people can hear sounds below 0 dB SPL in very quiet environments, and the actual threshold varies from person to person. Also, 0 dBm is 1 milliwatt, which is a specific power level, not silence.
Why do some formulas use 10 and others use 20? The 10 is used when the quantities being compared are already power (watts, milliwatts). The 20 is used when the quantities are amplitudes (volts, pascals, amperes) because the corresponding power ratio is the square of the amplitude ratio, and the square becomes a factor of 2 in the logarithm. If you are ever unsure, convert everything to power first, then use 10.
Related
Formula used
in p1 | Power or amplitude value 1 | - | 100 | 0.000001 | 1000000000 in p2 | Power or amplitude value 2 | - | 10 | 0.000001 | 1000000000 sel type | Quantity type | Power=1, Amplitude=2 out dB | Ratio in decibels | dB | (type == 1 ? 10 * log10(p1 / p2) : 20 * log10(p1 / p2)) | 2 out ratio | Linear ratio (p1/p2) | - | p1 / p2 | 3
Each line is one input (in, sel, list) or one result (out: label, unit, formula, decimals). How the calculators work
Method: the standard formula for this calculation, rounded as each result states. See how the calculators work or report an error.
- Zyn to Cigarette Ratio: Nicotine Equivalents15.0 cigarettes
- Zinc to Copper Ratio: Optimal Levels & How to Test
- Yield Strength to Modulus Ratio Explained
- Yen to Dollar Ratio: Live Rate & How It Works100.00 USD
- Watts to Decibels Conversion: How to Do It20.00 dB
- Vinegar to Water Ratio for Cleaning