help-calc

08 Numbers and Units

Calculate Decibels at Distance: Inverse Square Law

Card 08-0317 · Updated · Standard formula, shown below

Level at new distance 79.5 dB
Known level
90 dB
Input
Reference distance
3 ft
Input
New distance
10 ft
Input
You enter
Known level (dB), Reference distance (ft), New distance (ft)
You get
Level at new distance (dB)
Rounding
1 dp

This calculator works out how the sound pressure level (SPL) in decibels changes as you move away from a point source. You enter the known decibel level at a reference distance and the new distance, and you get the expected level at that new distance. It uses the inverse square law, which applies to sound radiating freely in all directions from a small source.

Formula

The inverse square law for sound intensity states that intensity decreases with the square of the distance from the source. In decibels, that becomes:

L₂ = L₁ − 20 × log₁₀(d₂ / d₁)

Where:

  • L₁ = known sound pressure level at the reference distance (dB)
  • d₁ = reference distance from the source (any unit, as long as d₂ uses the same)
  • d₂ = new distance from the source (same unit as d₁)
  • L₂ = calculated sound pressure level at the new distance (dB)

The 20 factor comes from the fact that sound pressure is proportional to the square root of intensity, and decibels use a base-10 logarithm. The formula assumes a free field, no reflections, and a point source.

Worked Example

Using the default values: known level 90 dB at 3 ft, new distance 10 ft.

  1. Compute the distance ratio: d₂ / d₁ = 10 / 3 = 3.3333
  2. Take the base-10 logarithm: log₁₀(3.3333) ≈ 0.5229
  3. Multiply by 20: 20 × 0.5229 = 10.458
  4. Subtract from the known level: 90 − 10.458 = 79.542 dB

The result rounds to 79.5 dB, which matches the calculator’s output.

When to Use This Calculation

This is useful for estimating sound levels in open outdoor spaces, such as predicting how loud a speaker will be at the back of a field, or how much noise from a machine reaches a neighboring property. It also helps in audio system setup, environmental noise assessment, and basic acoustics education.

The result tells you the expected SPL at the new distance. A difference of 6 dB represents a doubling or halving of pressure (perceived as roughly a noticeable change in loudness), while a 10 dB change is perceived as about twice or half as loud to human ears.

Common Mistakes

  • Mixing units: Using feet for one distance and meters for the other. Always convert to the same unit first.
  • Forgetting the 20 factor: Some use 10 instead of 20, which is correct for intensity (power) but not for pressure. Sound level meters measure pressure, so 20 is correct.
  • Assuming free-field conditions indoors: Reflections from walls, floors, and ceilings add energy, so the measured level will be higher than the calculated value.
  • Using the formula for line sources: For a long pipe or highway, sound decays at 10 dB per doubling of distance, not 20 dB. This formula only applies to point sources.
  • Ignoring atmospheric absorption: At high frequencies and long distances, air absorbs sound, causing additional loss beyond the geometric spreading.

Tips

  • Keep both distances in the same unit—use feet or meters consistently.
  • For a quick estimate, remember that every doubling of distance reduces the level by 6 dB.
  • If you need to find the distance at which a certain level occurs, rearrange the formula: d₂ = d₁ × 10^((L₁ − L₂)/20).
  • Use this calculator for planning outdoor events or speaker placement, but always verify with a real sound level meter if safety or compliance is involved.
  • For indoor spaces, expect higher levels than calculated due to reflections; a rough rule of thumb is to add 3 dB for each reflective surface nearby, but this is very approximate.

Troubleshooting

Result is negative or zero? Check that the new distance is not smaller than the reference. If d₂ < d₁, the formula gives a higher level (which is correct, as you are closer). If you get a negative level, it means the source is extremely weak or the distance is huge; sound levels below 0 dB are possible but rare in practice.

Result seems too low? If you’re indoors, reflections are boosting the actual level. Move to an open field or use a directional source to match the model better. Also check for atmospheric absorption at high frequencies.

Result doesn’t match a real measurement? Real-world sources are not perfect point sources. A large speaker array or a long machine radiates differently. Also, wind and temperature gradients can bend sound paths. For critical applications, measure with a calibrated meter.

Calculator shows “Cannot compute”? This happens if the new distance is zero or negative, or if the distance ratio is zero (which would require d₂ = 0). Ensure both distances are positive numbers.

Frequently Asked Questions

Q: Does the inverse square law apply to all sound sources?
A: No. It applies to point sources in a free field (no reflections). For line sources (like a long pipe), the decay is 10 dB per distance doubling. For planar sources (like a large panel), there is no decay until you get far away.

Q: Why is it 20 dB per decade, not 10?
A: Decibels for sound pressure use 20 × log₁₀(p/p₀). Since pressure is proportional to 1/distance, the log of 1/d becomes negative, giving a drop of 20 dB per decade (tenfold distance increase). If you were measuring sound intensity (power per area), it would be 10 dB per decade.

Q: How much does distance affect perceived loudness?
A: A 10 dB decrease is perceived as roughly half as loud, and a 20 dB decrease as a quarter as loud. Doubling distance gives about a 6 dB drop, which is a noticeable but not dramatic change.

Q: Can I use this for underwater sound?
A: Yes, the inverse square law applies in any homogeneous medium, but absorption is different. Underwater, low frequencies travel far, but high frequencies are absorbed quickly. The geometric spreading part is the same.

Q: What is the difference between sound pressure level and sound power level?
A: Sound power level (SWL) is the total acoustic energy emitted by a source, measured in dB relative to 10⁻¹² watts. Sound pressure level (SPL) is the pressure at a specific point, measured in dB relative to 20 µPa. This calculator deals with SPL.

Q: Does temperature or humidity affect the calculation?
A: Not for the geometric spreading part. However, atmospheric absorption increases with frequency, humidity, and temperature. At distances over 100 m and frequencies above 1 kHz, you may need to subtract additional absorption losses.

Related

Formula used
in spl | Known level | dB | 90 | 0 | 200
in d1 | Reference distance | ft | 3 | 0.1 | 10000
in d2 | New distance | ft | 10 | 0.1 | 10000
out spl2 | Level at new distance | dB | spl - 20 * log10(d2 / d1) | 1